DSC Large Aluminum Pan

$105.00

Quantity: 200 Pans
Material: Aluminum
Dimensions: 6.7 x 1.7 mm
Features: Deep pan for higher sample volumes
Uses: Replacement Consumable for TA Instruments Differential Scanning Calorimeter: Q10, Q100, Q1000, Q20, Q200, Q2000, and others.

Note:Not a direct replacement for TA Instrument’s 900786.901 parts due to higher volume and slight diameter difference. Product does not fit with TA Instrument crimping tools.

Compare to OEM P/N: 900786.901
P/N: 5416717.2

Country of Origin: USA

SKU: 5416717.2 Category: Tags: , , , ,

Description

DSC Pan (6.7 x 1.7 mm)

Quantity: 200 Pans
Material: Aluminum
Features: Deep pan for higher sample volumes
Uses: Replacement Consumable for TA Instruments Differential Scanning Calorimeter: Q10, Q100, Q1000, Q20, Q200, Q2000, and others.
Country of Origin: USA

Used With:
“Press to Fit” DSC Aluminum Pan Style Cover: 5316500.2

Alternative Items:
DSC Large Volume Aluminum Pan (6.7 x 1.7 mm) and Pan Style Cover Kit: 5016717.2
DSC High Volume Aluminum Pan (6.7 x 2.7 mm): 2416727.2

Engineering a Better Pan…

This product has been specifically designed and tested to work with TA Instruments branded DSCs. The aluminum impurities were altered/added to stiffen the pan to resist bottom deformation sometimes seen when mechanically crimping high modulus of elasticity (low deformation) samples. Each lot undergoes high speed DSC runs (greater sensitivity) for quality control.

Temperature Range: -170 to 600 oC
Volume Range: 0 – 40 mL
Max Recommended Volume*: 13.33 mL (1/3 of total)
Max-Plus Volume**: 20 mL
Max Pressure: 1 atm

 

*Max Recommended Volume: Samples of this volume or less will generate the best data and are considered safe for system use.
**Max-Plus Volume: Samples with a volume greater than this are highly likely to cause the following errors or damage, each being dependent on the sample composition: pan deformation, inaccurate transition data, spillage/overflow, or cell damage.

Pan and lid sets are “Press to Fit” crimped to hold the sample in place, but not hermetically sealed.

For an introduction to the Differential Scanning Calorimeter (DSC) and it’s capabilities, watch our free video here.
_______________________________
In deference to the Original Manufacturers
“Neither EA Labs nor Thermal Support LLC are affiliated with TA Instruments, Waters Corporation, or its affiliates. All claims of compatibility with TA Instrument’s products are the sole claim of Thermal Support, and have not been reviewed, approved, or endorsed by TA Instruments, Waters Corporation, or its affiliates.”


Terms of Sale | MSDS

Additional information

Weight 24 oz
Dimensions 12 × 9 × 2 in

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

TopBack to Top